Acksen PC Based Temperature Monitor & Logger

The DS-108 PC Based Temperature Monitor & Logger monitors and records temperatures and the status of digital inputs. The standard temperature probe lead length is 2m (6ft). Works within the range of -50°C to +150°C (-58°F to +300°F).

The DS-108 Temperature Monitor & Logger is ideally suited for use in situations where it is a requirement to record multiple temperature inputs and/or digital ‘logic’ inputs. For example, in a commercial refrigerator, the range of temperatures over a period of time, compresssor on/off, door open/closed, fan on/off. The DS-108 has the capability to answer all of these questions.

The data recorded by the DS-108 is saved in CVS/text file format on PC.

Acksen PC Based Temperature Monitor & Logger features include:

  • 8 digital temperature inputs, plus internal (ambient).
  • 8 digital logic input inputs, from 0V to +30V (DC)
  • 5Vdc/400mA output for external circuitry.
  • Connection via USB to PC software (provided).
  • Sample rate (all 17 channels), 1 sample per second, saved to disk every 10 seconds.
  • Complete analysis and logging software, °C, °F or K.
  • Software displays dashboard, shows graph and saves the data to disk.

Standard Set includes:

  • data logger
  • 4 digital temperature probes (2m leads)
  • USB-B lead
  • software
  • carry case

Acksen DS-108 PC Based Temperature Monitor & Logger Datasheet

Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help.

DC-3V Three Channel Voltage Logger

The DC-3V is ideal for monitoring and recording one, two or three channels of DC voltages from 1Vdc to 300Vdc, for example from batteries, circuit breaker trip batteries, charging circuits, power supplies, photovoltaic (PV) cells, DC motor circuits, DC Generators, DC telecoms circuits…  We can extend the range to 300Vdc if needed.

Using appropriate transducers or signal conditioners, you can record many parameters, temperature, solar irradiation, wind speed.

DC-3V Three Channel Voltage Logger Features

  • Ideal for industrial logging
  • Voltage Range: 60V or 300V
  • Voltage Accuracy: 1V – 5V < 2%, 60V model, 6V – 60V < 1%. 300V model 60V – 300V ~2%
  • CAT Rating: CAT II
  • Recording Period: 1 sec to 60 mins
  • Recording Standard: Recording – EN50160: 1994
  • Environmental Sealing: IP43 as standard, available as IP65/NEMA 12/4
  • Size & Weight: Metric – 260x180x190mm & 2kg

DC-3V  Kit includes

  • 60V Data Logger
  • Unfused Voltage Input Leads
  • USB Lead
  • 12Vdc PSU
  • Electrosoft Software
  • Carry Case

DC-3V Three Channel Voltage Logger data sheet

Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help

CT-1A Single Phase Current Logger

The CT-1A data logger is used by householders, companies, facilities management, power management and optimisation companies to monitor loads from 0.1A to 100A, model dependent. It can be used for energy audits and the monitoring and logging of new low energy products, eg, LED lighting, low energy bulbs.

It can be used to record earth leakage currents, providing the currents are over 0.1A.The current transformer breaks open, allowing it to be placed around the cable without having to break the main circuit.

CT-1A Single Phase Current Logger FEATURES

  • Ideal for industrial logging
  • Current Range: 10A, 50A or 100A
  • CTs fit around 30mm cables
  • Current Accuracy: ±2% of range, typically
  • Records true RMS Iavg, Imax & Imin
  • Recording Period: 1 sec to 60 mins
  • Recording Standard: Recording – EN50160: 1994
  • Environmental Sealing: IP65 as standard
  • Size & Weight: Metric – 126x75x45mm & 300g

CT-1A KIT Includes

  • Data Logger
  • Voltage Input Lead
  • One Clamp-On CT
  • RS-232 Serial Lead
  • Electrosoft Software
  • Carry Case

Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help

EC-1A Single Phase Current Logger

The EC-1A data logger is used by power distribution companies, facilities management, power management and optimisation companies to monitor loads from 5A to 10kA, model dependent. It can be used for energy audits and the monitoring and logging of new low energy products, eg, LED lighting, low energy bulbs….at the other end of the spectrum it can be used to highlight real loading problems. Note, the Rogowski Coil breaks open at the black joint, allowing it to be placed around the cable without having to break the main circuit.

EC-1A Single Phase Current Logger Features

  • Ideal for industrial logging
  • Current Range: 400A, 1kA, 2kA or 3kA
  • Rogowski Coils fit around 140mm cables
  • Current Accuracy: ±2% of range, typically
  • CAT Rating: CAT III
  • Records true RMS Iavg, Imax & Imin
  • Recording Period: 1 sec to 60 mins
  • Recording Standard: Recording – EN50160: 1994
  • Environmental Sealing: IP65 as standard
  • Size & Weight: Metric – 250x175x70mm & 1kg

EC-1A Kit Includes

  • Data Logger
  • Rogoswski Coil
  • USB Lead
  • 12Vdc PSU
  • Electrosoft Software
  • Carry Case

Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help

 

EC-3A Three Phase Current Logger

The EC-3A is used to determine feeder loading and mainly used by power distribution companies, heavy industry, facilities management, electrical or site services and maintenance engineers to monitor loading variations on site helping them to diagnose any related issues, transformer and feeder sizing problems. Perfect for gathering data to make a case for splitting-up the loading or increasing circuit capacity.

EC-3A Three Phase Current Logger Features

  • Ideal for industrial logging
  • Current Range:  400A, 1kA, 2kA or 3kA
  • Rogowski Coils fit around 140mm cables
  • Current Accuracy: ±2% of range, typically
  • CAT Rating: 1000V CAT III, 600V CAT IV
  • Records true RMS Iavg, Imax & Imin
  • Recording Period: 1 sec to 60 mins
  • Recording Standard: Recording – EN50160: 1994
  • Environmental Sealing: IP65 as standard
  • Size & Weight: Metric – 260x180x190mm & 2kg

EC-3A  Kit Includes

  • Data Logger
  • Rogoswski Coils
  • USB Lead
  • Electrosoft Software
  • Carry Case

Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help

EC-3V Three Phase Voltage Logger

The EC-3V is used by power distribution companies, voltage and energy optimisation companies, facilities management, electrical or site services and maintenance engineers to monitor voltage variations on site helping them to diagnose any voltage related issues, or to gather data perhaps to make representations to their power supplier. Voltage optimisation companies also use the product to monitor voltage levels pre and post optimisation.

The EC-3V has native USB communications and has a phase sequence (rotation) checker as standard.

EC-3V Three Phase Voltage Logger Features

  • Ideal for industrial logging
  • Voltage Range: 500V
  • Voltage Accuracy: ±1% of reading ±1 Volt, 90Vac – 450Vrms (ph – ph); else ±3%. (50/60Hz ±2%)
  • CAT Rating: CAT III
  • Recording Period: 1 sec to 60 mins
  • Recording Standard: Recording – EN50160: 1994
  • Environmental Sealing: IP43 as standard, available as IP65/NEMA 12/4
  • Size & Weight: Metric – 250x175x70mm & 500g

EC-3V Kit Includes

  • Data Logger
  • Voltage Input Leads
  • USB Lead
  • Electrosoft Software
  • Carry Case

Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help.

EC-2VA Single Phase Voltage & Current Logger

The EC-2VA data logger is used by power distribution companies, facilities management, electrical or site services and maintenance engineers to monitor both voltage and current variations. This helps them to diagnose any related issues, or to gather data perhaps to make representations to their power supplier.

As the product records both voltage and current, users can determine if low voltage is related to high current demands on site, or if the low voltage is being supplied to the site.

EC-2VA Single Phase Voltage & Current Logger Features

  • Ideal for industrial logging
  • Voltage Range: 300Vrms
  • Current Range: 300A
  • Rogowski Coils fit around 140mm cables
  • Voltage Accuracy: ±2% of reading (10 bit) within 90Vac – 300Vrms otherwise ±3%. (50/60Hz ±2%)
  • Current Accuracy: 2% of range, typically
  • CAT Rating: 1000V CAT III, 600V CAT IV
  • Recording Period: 1 sec to 60 mins
  • Recording Standard: Recording – EN50160: 1994
  • Environmental Sealing: IP65 as standard
  • Size & Weight: Metric – 145x90x45mm & 500g

EC-2VA Kit Includes

  • Data Logger
  • Voltage Input Lead
  • Rogowski Coil
  • RS-232 serial lead
  • Electrosoft software
  • Carry Case

Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help.

 

EC-7VAR Three Phase Voltage, Current & Power Factor Data Logger

The EC-7VAR PQA is used by electrical contractors, power distribution companies, facilities management, electrical or site-services and maintenance engineers. It is used to monitor power (kW)/energy (kWh) usage, check voltage and current variations helping them to diagnose any related issues, or to gather data perhaps to make representations to their power supplier.

Widely used for UPS sizing and monitoring and standby generator sizing and monitoring. As the product records both voltage and current, users can determine if low voltage is related to high current demands on site, or if the low voltage is being supplied to the site.

EC-7VAR Three Phase Voltage, Current & Power Factor Data Logger Features:

  • Ideal for industrial logging PQA
  • Voltage Range: 500Vac
  • Current Range: 400A, 1kA, 2kA or 3kAac
  • Rogowski Coils fit around 140mm cables
  • Voltage Accuracy: ±1% of reading, ±1 Volt. (10 bit) within 100Vac-450Vrms (ph–ph); else ±3%. (50/60Hz ±2%)
  • Current Accuracy: ±2% of reading, typically (within 10% – 90% of full scale), otherwise 3% of full scale
  • Power Factor Accuracy: Accurate to ~3% between lead 0.5 and 0.5 lag; ~6% between 0.5 and 0.3 lead or lag
  • CAT Rating: 1000V CAT III, 600V CAT IV
  • Records true RMS Vavg, Vmax & Vmin to 2%
  • Records true RMS Iavg, Imax & Imin to 5%
  • Recording Period: 2 sec to 60 mins
  • Recording Standard: EN50160: 1994
  • Environmental Sealing: IP43 as standard, available as IP65/NEMA 12/4
  • Size & Weight: Metric – 260x180x190mm & 2kg

EC-7VAR  Kit Includes

  • Data Logger
  • Rogowski Transducers
  • Voltage Leads
  • USB Lead
  • Electrosoft Software
  • Carry Case

EC-7VAR Three Phase Voltage, Current & Power Factor Data Logger data sheet

Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help.